You are here:

Repeater Power Supply DC 52100

Powering and Isolation of 2- and 3-wire Transmitters

The repeater power supply DC 52100 is used to supply and separate 2- and 3-wire transmitters and active sensor signals.

  • Universal operation of Transmitters
    Energization and separation of field located 2-, 3- and 4-wire transmitters with current or voltage output
  • Calibrated signal setting
    Input and output range can be set by using DIP switch – high precision without any further adjustment
  • 3-Port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design
    6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector
    allows for fast and economical installation
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

The repeater power supply supplies the transmitter with power and transmits the current or voltage measuring signal with high accuracy galvanic isolated to the output. Alternative the measuring input accepts active signals from 4-wire transmitters.

The input and output range of DC 52100 can be easily set by using DIP switch. Due to the calibrated range selection no further adjustment is necessary.

The auxiliary power can be supplied via the connection terminals or via the optional In- Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply.

Product line

Product line DC 52100
Device Type Order No.
Repeater Power Supply, calibrated range selection DC 52100 S
Repeater Power Supply, calibrated range selection,
In-Rail-Bus for power supply
DC 52100 B

Technical Data

Input

Input signal
(calibrated switchable)
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V
Input resistance Current input ≤ 25 Ohm Voltage input ≥ 100 kOhm
Overload 50 mA / 30 V
Transmitter supply (Tx) 16 V (open circuit voltage/short circuit current < 22 V/35 mA)

Output

Output signal
(calibrated switchable)
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V
Load Current output
Voltage output
≤ 12 V (600 Ohm at 20 mA)
≤ 5 mA (2 kOhm at 10 V)
Linear transmission range –1 to +110 %
Residual ripple < 10 mVrms

General Data

Transmission error < 0.1 % full scale
Temperature coefficient 1) < 100 ppm/K
Cut-off frequency -3 dB 5 kHz, 100 Hz, switchable
Response time T99 150 µs, 7 ms
Test voltage 3 kV AC, 50 Hz, 1 min, Input against output against
power supply
Working voltage 2)
(Basic Insulation)
600 V AC/DC for overvoltage category II and pollution
degree 2 acc. to EN 61010-1
Protection against electrical shock 2) Protective separation according to EN 61140 by reinforced
insulation in accordance with EN 61010-1 up to 300 V AC/DC
for overvoltage category II and pollution degree 2
Ambient temperature Operation
Transport and storage
–25 °C to +70 °C   (-13 to +158 °F)
–40 °C to +85 °C   (-40 to +185 °F)
Power supply 24 V DC, 16.8 V to 31.2 V DC, approx. 1.3 W
EMC 3) EN 61326-1
Approvals UL (USA/Canada): UL 61010, Class I, Div. 2
ATEX / IECEx: Zone 2 (nA)
Construction 6.2 mm (0.244") housing, protection class: IP 20
mounting on 35 mm DIN rail acc. to EN 60715
Connection Captive plus-minus clamp screws
Wire cross-section max. 2.5 mm² / AWG 14
Stripped length 6 to 8 mm / 0.28 in
Screw terminal torque 0.8 Nm / 7 lbf in
Weight Approx. 70 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • 1 + Transmitter supply voltage U Tx
  • 2 + Input current
  • 3 − Input GND
  • 4 + Input voltage
  • 5 + Output
  • 6 − Output
  • 7 + Power supply 24 V DC
    (connected to In-Rail-Bus)
  • 8 − Power supply 24 V DC
    (connected to In-Rail-Bus)

Optional power connection via In-Rail-Bus (see accessories)

Subject to change!

Back to the product list

Product request

Please calculate 7 plus 5.