You are here:

Transmitters

Mesuring ranges:
Fixed ranges within 20 Ohm to 1 MOhm, see product line

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Input signal:
Potentiometer 100 Ohm to 100 kOhm

Output signal:
0 to 20 mA, 4 to 20 mA, ±20 mA, 0 to 10 mA, 2 to 10 mA, ±10 mA, 0 to 10 V, 2 to 10 V, ±10 V, 0 to 5 V, 1 to 5 V, ±5V

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation, protective separation, housing width: 12.5 mm

Sensor input:
Pt 100, 4-wire connection

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Ranges:
-100 to +450 °C  (32 Types)

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Sensor input:
Pt 100, Pt 1000

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V

Ranges: -100 to +600 °C

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, sensor diagnostics, protective separation, housing width: 12.5 mm

Sensor input:
Pt 100, 2- or 3-wire connection

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Ranges:
-100 to +450 °C  (32 types)

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Sensor input:
Pt 1000, 2- or 3-wire connection

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Ranges:
-100 to +450 °C  (32 types)

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Sensor Input:
Resistors: Pt 100, Pt 200, Pt 500, Pt 1000, Ni 100, Ni 200, Ni 500, Ni 1000;
Thermocouple: B, E, J, K, L, N, R, S, T, U, W5Re_W26Re, W3Re_W25Re;
KTY, resistor, mV and potentiometer measuring

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 mA, 2 to 10 mA
0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V

Measurement Ranges:
-270 to +2315 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Pt 100, Pt 200, Pt 500, Pt 1000, Pt 2000, JPt 50, JPt 100

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-200 to +850 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Ni 100, Ni 200, Ni 500, Ni 1000, acc. DIN 43760 (TK6180)
Ni 120 (TK6720), Ni 1000 (TK5000), Ni 1000 (TK6370)

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-50 to +250 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Measuring input for all KTY temperature sensors

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-50 to +300 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Thermocouple Type A, B, C, D, E, J, K, L, N, R, S, T, U

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-200 to +2500 °C, according to type of thermocouple

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm